Glass Times editor Luke Wood talks to Andy Jones, director of GlassCheck UK, about why the new testing and compliance service has been launched to assist glass and IGU manufacturers with compliance to BS EN 1279.

Luke Wood: Andy, you’ve launched GlassCheck UK in response to news that the Office for Product Safety and Standards (OPSS) will be scrutinising IGU manufacturers, specifically with regards to BS EN 1279, the standard that covers the volume of gas content within glass units. Can you give us some background on this, and why it’s so important that IGU manufacturers should be aware of the situation?
Andy Jones: I was inspired to launch GlassCheck UK following the OPSS report earlier this year on companies manufacturing heat-soaked toughened glass.

Advertisement Advertisement

Of the 28 companies that were audited, 100% were found to be non-compliant. A third of them were actually given prohibition orders to stop manufacture, while 25 out of the 28 were given letters requiring them to improve.

I’ve been in the industry for 40 years, and that made me think: if that many companies are failing to comply with the requirements for heat-soaked glass, how many will be compliant with EN 1279?

When you consider the level of non-compliance found with heat-soaked glass, and the fact that there are around 651 IGU manufacturers in this country, how many of those will be non-compliant?
And how can I help with that? That’s really how GlassCheck UK came about.

Luke Wood: For those who aren’t aware, can you clarify what the OPSS is, and why it has the power to enforce these regulations?
Andy Jones: The OPSS (Office for Product Safety and Standards) is the national product regulator for the UK. Its primary purpose is to protect people and places from product related harm ensuring that consumers and businesses can buy and sell products with confidence.

The OPSS is essentially the enforcement authority not just for our industry, but for any industry that supplies into the building envelope. Its job is to enforce and ensure that safety and compliance standards are being adhered to, and that what you are manufacturing is accurately reflected in your Declaration of Performance (DoP).

The OPSS has most recently scrutinised manufacturers of heat-soaked glass. It looked at fire doors last year, and it has far reaching powers – including the power to issue a prohibition order on non-conforming products, as well as the power to recall products that have already left the factory.

So, if you’ve supplied products that don’t comply, you can be ordered to remake them. That has the potential to massively disrupt working relationships, supply chains and cash flow, particularly at a time when the market is already down.

Luke Wood: So how can you, as GlassCheck UK, help IGU manufacturers prepare for an audit by the OPSS? And perhaps you could explain why employing your services can be more cost-effective than simply buying the equipment required to measure gas levels?

Andy Jones: If the OPSS makes an inspection, which may be unannounced, it can ask for evidence relating to all six parts of EN 1279, including Part 6, which covers periodic and on-going testing. That’s where GlassCheck UK can help, specifically with gas concentration testing.

Part 6 recommends that ongoing testing for gas concentration should cover three units per 1,000 units manufactured per day, per line, as a minimum requirement.

So, whether you’re making 10 units or 999 units a day, you should still be testing a minimum of three units per line, per day, per line.

There are only two ways of testing gas concentration in IGUs: destructive or non-destructive.
Destructive testing means you make a sealed unit and drill a hole through it. You then place a device in that hole to accurately measure the gas content within the unit.

However, as the name suggests, destructive testing means the integrity of the units is destroyed during the test process and therefore is unusable for sale.

The OPSS doesn’t want to see destructive testing carried out on units specifically made for testing. It wants to see units taken from the production line. That makes it expensive because the testing equipment is expensive, the materials used are scrapped and production time is lost. When added up over a week/month/year this can equate to many thousands of pounds.

Non-destructive testing includes equipment from Sparklike, available from Inagas here in the UK. There is a handheld option from Sparklike, but although this works well with standard double glazed units, the handheld device cannot measure through coatings, which is a problem, particularly as solar coatings are becoming more popular and we generally always have at least one low e coating within the make-up of the unit.

It also cannot test triple glazing, which is a significant issue considering that triple glazing is increasingly becoming part of the market. The OPSS view is fairly straightforward, if you are not testing it then you should not be selling it, therefore if the OPSS was doing an audit on your EN 1279 compliance and you could not evidence testing with a calibrated device whether that be destructive or non destructive then you should not be offering that product for sale.

The equipment we use also comes from Sparklike but uses laser technology. It can test coated glass, double-coated glass and triple glazing, and is far more accurate.

Our offering is that we will come into your business, whether that’s weekly, bi-weekly or monthly, and measure up to 50 units per visit. We then provide you with the results in a dated report, giving you the evidence you need to demonstrate compliance of gas concentration testing.

It is possible to do the non-destructive testing yourself, but the equipment from Sparklike represents a significant investment, and there’s also the time and expertise involved in carrying out the testing and the ongoing cost of calibration which itself is several thousand pounds per year.

There is a cost for our services, but it’s very cost competitive when compared with the cost of destructive testing and if compared against the cost of non-compliance it is a drop in the ocean when you take into account the potential cost of lost business, a product recall or indeed the reputational damage receiving a prohibition order could cause.

It should also be said that, for IGU manufacturers, compliance should be built into the price of your product. It’s not a nice-to-have; it’s a legal requirement, and that cost should be reflected in the end product in the same way as your production and material costs are.

Luke Wood: When you consider the nature of the materials and processes involved in filling IGUs, historically it has been very difficult to police. What are your thoughts on this, and how complacent do you think the industry has been to date?
Andy Jones: The majority of companies should be doing some sort of testing, but I don’t think many will be doing it on triple glazing because, historically, the only option has been destructive testing, and that is expensive.

If the OPSS finds that out, it could stop that company from making triple glazing until it can provide evidence that it is testing.

I would hope the majority of those producing double-glazed IGUs will be testing, but, truthfully, I don’t think many companies are doing it well enough to meet the full requirements for compliance.

I am fearful that the industry has become complacent because we have never really been policed before.

The OPSS will be looking for proof that you are compliant. How can you prove that the products leaving your door are in line with your Declaration of Performance?

When it came to heat-soaked toughened glass, 100% of the companies audited failed to demonstrate sufficient compliance with the relevant standards. I would hope that we don’t see this with EN 1279 however I am fearful that a large majority of IGU’s will fail at some level. Unfortunately, you cant be nearly compliant, you are either compliant or not.

The difference is that with heat-soaked glass, it’s only a relatively small amount of product that is affected and is generally not a core product line. With EN 1279, if you’re manufacturing IGUs, then it potentially applies to 100% of what you sell.

So, it could massively impact businesses. In my 40 years in this industry, I think it is the biggest potential challenge the industry has faced with in that period.

The challenge is huge for companies, but it’s real, it’s here and it’s now.
If companies are not compliant, they need to ensure they achieve compliance before they get a knock on the door from the OPSS. The visits will be unannounced, and the organisation has real teeth, with potentially serious ramifications for your business.

I’ve spoken to a lot of IGU companies in the last few months, and the first question a lot of them ask is, “Andy, how do we get around this?” But there is no getting around it. You must be compliant.

That said, we should not see the OPSS as the big bad wolf.

All the OPSS is doing is making sure that what you are selling meets the legal standards and matches what you are declaring in your DoP.

So, if you’re doing all the testing correctly, you’ve got nothing to hide. But if you’re not, then that’s on you, not the OPSS. They’re just policing it.

And it’s not just glass manufacturers. The emphasis is also on installers to be legally compliant. They should be ensuring that whatever they are installing, they have a copy of the DoP for that product, and they also have the evidence of that compliance. Ultimately the buck stops with the company installing the product to ensure that all products are meet the legal requirements, it is not acceptable just to take someone’s word for it because “that is what we have always done”. That is not a defence in a court of law.

It could ultimately be a good thing. It could get rid of those that aren’t compliant and have been getting away with it. But companies that are playing by the rules will also need to make sure they are doing everything properly and, importantly, that they can properly evidence their compliance.